Warning

JFolder::create: Could not create folder.Path: /home/agus1975/watermart.co.id
Key folder in safepath unaccessible

Desal AG8040F

Print
The A-Series, family of proprietary thin-film reverse osmosis membrane elements are characterized by high flux and excellent sodium chloride rejection. AG High Rejection Brackish Water Elements are selected when high rejection and operating pressures as low as 200 psig (1,379 kPa) are desired.
Description

The A-Series, family of proprietary thin-film reverse osmosis membrane elements are characterized by high flux and excellent sodium chloride rejection. AG High Rejection Brackish Water Elements are selected when high rejection and operating pressures as low as 200 psig (1,379 kPa) are desired. These elements allow moderate energy savings, and are considered a standard in the industry. AG8040F High Rejection Brackish Water elements feature a FRP outerwrap and 31 mil feed spacers. This element is designed with flush end connections.

 

  • GE Desal AG8040F RO Element TFC:
  • The GE Desal AG8040F Dry, Flush Cut reverse osmosis elements are used for brackish water desalination.
  • The A-Series thin-film reverse osmosis membrane elements are characterized by high flux and excellent sodium chloride rejection.
  • GE Osmonics Desal AG8040F High Rejection Brackish Water reverse osmosis elements feature a FRP outerwrap and 27 mil feed spacers and is designed with flush end connections.
  • GE Desal AG High Rejection Brackish Water Elements are selected when high rejection and operating pressures as low as 200 psig are desired.
  • These elements allow moderate energy savings, and are considered a standard in the industry.

 

Element Specifications

 

Model : AG8040F

 

Flow : 9200 GPD (34.8 m3/d)

 

Active Area : 350 ft2 (32.5 m3)

 

Avg. Rejection : 99.5%

 

Min. Rejection : 99%

 

Part Number : 1206779

 


Specifications are based on a 2000 mg/L NaCl solution at 225 psig operating pressure (1551 kPa), 77°F (25°C), 15% recovery, pH
7.5 after 24 hours. Individual flux may vary +25%/ -15%.

 

Operating and Design Parameters

 


Membrane: Thin Film Membrane (TFM®)

 

Typical Operating 200 psig (1,379 kPa)

 

Pressure:

 

Maximum Pressure: 450 psig (3,103 kPa)

 

Maximum Temperature: 122°F (50°C)

 

Chlorine Tolerance: 1,000 ppm-hrs, dechlorination recommended

 

Optimum Rejection pH: 7.0 -7.5

 

Operating pH Range: 4.0 - 11.0

 

Cleaning pH Range: 2.0 - 11.5

 

Feed NTU: <1

 

Feed SDI: <3

 

Maximum Pressure Drop : 10 psig (69 kPa) per element, 50 psig (345 kPa) per vessel

 

Element Dimensions and Weight

 

Model : AG8040F

 

Dimension A : 40" (1,016 mm)

Dimension B : 1.125" (29 mm)

Dimension C* : 7.88" (200 mm)

 

Weight : 32.0 lbs (14.5 kg)